No-Burn® Plus ThB Now Over Lapolla Open and Closed Cell Foams: 100 – 115 sq. ft. Per Gallon

NO-BURN® PLUS THB THERMAL BARRIER NOW OVER LAPOLLA OPEN AND CLOSED CELL FOAMS: 100 – 115 SQ. FT. PER GALLON TABLE 2 –ALTERNATIVE THERMAL BARRIER ASSEMBLIES SUBSTRATE NO-BURN® PRODUCT NAME MAXIMUM THICKNESS (in) Walls & Vertical Surfaces MAXIMUM THICKNESS (in) Ceilings, Underside of Roof Sheathing/Rafters & Floors APPLICATION OF NO-BURN® COATING MINIMUM INSTALLED THICKNESS (mils) THEORETICAL APPLICATION RATE (gallons per 100 square feet) …

Read more

No-Burn® Plus ThB Now Over Johns Manville (JM) Open and Closed Cell Foams: 115 sq. ft. Per Gallon

NO-BURN® PLUS THB THERMAL BARRIER NOW OVER JOHNS MANVILLE (JM) OPEN AND CLOSED CELL FOAMS: 115 SQ. FT. PER GALLON ALTERNATIVE THERMAL BARRIER ASSEMBLIES Table 2 in Evaluation Report (ER) 305   SUBSTRATE   NO-BURN® PRODUCT NAME MAXIMUM THICKNESS (in) Walls & Vertical Surfaces MAXIMUM THICKNESS (in) Ceilings, Underside of Roof Sheathing/Rafters & Floors APPLICATION OF NO-BURN® COATING MINIMUM INSTALLED …

Read more

No-Burn® Plus ThB Thermal Barrier Now Over SWD Open and Closed Cell Foams

NO-BURN® PLUS THB THERMAL BARRIER NOW OVER SWD OPEN AND CLOSED CELL FOAMS: 115 SQ. FT. PER GALLON ALTERNATIVE THERMAL BARRIER ASSEMBLIES Table 2 in Evaluation Report (ER) 305 SUBSTRATE NO-BURN® PRODUCT NAME MAXIMUM THICKNESS (in) Walls & Vertical Surfaces MAXIMUM THICKNESS (in) Ceilings, Underside of Roof Sheathing/ Rafters &Floors APPLICATION OF NO-BURN® COATING MINIMUM INSTALLED THICKNESS (mils) THEORETICAL APPLICATION RATE (gallons …

Read more

Update Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene

NO-BURN® PLUS THB CONTINUES TO EXCEL!  IAPMO Evaluation Report (ER) 305 HIGH COVERAGE RATES WITH AGGRESSIVE PRICING WILL IMPROVE YOUR PROFITABILITY SUBSTANTIALLY! ALTERNATIVE THERMAL BARRIER ASSEMBLIES Table 2 in Evaluation Report (ER) 305   SUBSTRATE NO-BURN® PRODUCT NAME MAXIMUM THICKNESS (in) Walls & Vertical Surfaces MAXIMUM THICKNESS (in) Ceilings, Underside of Roof Sheathing/ Rafters &Floors APPLICATION OF NO-BURN® COATING   …

Read more

SPFA 2018 Exhibitor No-Burn, Inc. – Booth # 325

SPFA 2018 Exhibitor No-Burn®, Inc. – Booth # 325 Visit booth 325 for the latest No-Burn® updates.  On January 31 – February 1, No-Burn® representatives are on-site to discuss new test data, provide fire protective solutions for your next project, and more. No-Burn®, Inc. is a manufacturer of passive fire protective coatings known as intumescent and fire retardant …

Read more

Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene

Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene No-Burn® Plus ThB has successfully tested to meet IRC® and IBC® requirements as a component in an alternative thermal barrier assembly.  Plus ThB is an intumescent fire protective coating for interior spaces where spray polyurethane foam is installed, providing the fire protection and Class III vapor retardency as code requires …

Read more

Renewal of Evaluation Report, ER 305

No-Burn®, Inc. announces renewal of their code compliance Evaluation Report, ER 305.  The industry may utilize the Evaluation Report for compliance with the newest 2015 Edition of the I-Codes.  Renewal of ER 305 signifies No-Burn® continues to be compliant as an interior fire protective coating as prescribed by code, where required for: surface burning characteristics, alternate thermal and ignition barriers and …

Read more

Use of Topical Coatings with Weyerhaeuser Engineered Wood Products

Weyerhaeuser has recently released a technical bulletin allowing the use of topical coatings over their engineered wood products based upon certain parameters. No-Burn® Plus meets the topical coating requirements listed in Weyerhaeuser’s Technical Bulletin 310 (TB-310). No-Burn® Plus is code compliant, has a pH range of 7-8, is applied without pressure or soaking, and does not contain …

Read more